Lab scientists testing PFAS-free firefighter turnout gear revealing brominated flame retardants, with chemical highlights on fabric.
Lab scientists testing PFAS-free firefighter turnout gear revealing brominated flame retardants, with chemical highlights on fabric.
AI에 의해 생성된 이미지

Study finds brominated flame retardants in firefighter turnout gear, including newer PFAS-free models

AI에 의해 생성된 이미지
사실 확인됨

A U.S. study has found brominated flame retardants in firefighter turnout gear, including in newer models marketed as PFAS-free. Published on December 16 in Environmental Science & Technology Letters, the research reports that some of these flame retardants appear at higher extractable levels than PFAS in certain gear layers, raising fresh questions about potential health risks to firefighters.

Firefighter turnout gear, essential for protection during emergencies, is typically made up of three layers: a flame-resistant outer shell, a middle moisture barrier that blocks germs while allowing airflow, and an inner thermal layer designed to help regulate body temperature. According to Duke University, manufacturers apply chemical treatments to these textiles so they can meet safety standards developed by the National Fire Protection Association.

For several years, firefighters and researchers have raised concerns about per- and polyfluoroalkyl substances (PFAS), which are used in turnout gear to repel oil and water and can contribute to flame resistance. Numerous human and animal studies have linked PFAS exposure to health problems, including certain cancers and thyroid disease. Multiple U.S. states have passed laws that will prohibit the purchase of PFAS-treated turnout gear starting in 2027, prompting manufacturers to shift toward alternative chemistries.

The new study, led by Heather Stapleton of Duke University's Nicholas School of the Environment and published December 16 in the journal Environmental Science & Technology Letters, is described by Duke and ScienceDaily as the first U.S. research to formally document the use of brominated flame retardants in firefighter turnout gear.

The research team, which included scientists from Duke University and North Carolina State University's Wilson College of Textiles, analyzed nine sets of used turnout gear manufactured between 2013 and 2020 and three sets produced in 2024 that were marketed as non-PFAS treated. Using two analytical techniques, they tested each of the three layers of the gear for both PFAS and brominated flame retardants. This allowed them to measure the total amount of chemicals present and the fraction that could be extracted from the textiles, an indication of what might transfer during use through skin contact or inhalation.

PFAS were detected in all turnout gear manufactured between 2013 and 2020. In contrast, gear made in 2024 showed only low or non-detectable extractable PFAS levels, which the authors say indicates the garments had not been intentionally treated with PFAS, consistent with manufacturer claims. Small amounts that were found are thought to have come from environmental contamination rather than the manufacturing process.

Every set of gear in the study also contained brominated flame retardants, and the extractable levels of these compounds were generally higher than those measured for PFAS. The highest extractable concentrations of brominated flame retardants were reported in the 2024 gear marketed as non-PFAS treated, particularly in the moisture barrier layer. The authors say this pattern suggests that some manufacturers may have added brominated flame retardants to help the gear meet flammability requirements as PFAS were phased out from that layer.

Among the brominated flame retardants identified, decabromodiphenyl ethane (DBDPE) occurred at the highest extractable levels. The study notes that no U.S. research has directly examined health effects from DBDPE exposure in firefighters, but cites a 2019 study of workers at a chemical manufacturing plant in China that found associations between DBDPE exposure, altered thyroid hormone levels and signs of thyroid disease.

"I was really surprised that the manufacturers used DBDPE in turnout gear," Stapleton said, according to accounts from Duke University and outlets summarizing the study. She added that the compound has similar properties to decaBDE, a brominated flame retardant that has been largely phased out globally due to toxicity concerns.

For most gear manufactured between 2013 and 2020, the outer shell contained higher extractable concentrations of brominated flame retardants than the moisture barrier or inner lining. Stapleton said this pattern likely reflects accumulation from smoke and soot encountered during fires: when building materials burn, they can release brominated flame retardants into the air that adhere to gear and do not wash out easily.

At the same time, the presence of brominated flame retardants in the internal layers of some older sets suggests that certain manufacturers had been incorporating these chemicals into turnout gear treatments well before PFAS began to be phased out, the authors report.

Brominated flame retardants as a class have been associated in prior research with cancer, thyroid disease and neurodevelopmental or developmental problems. However, the Duke-led team emphasizes that firefighters' specific exposure levels to the substances identified in this study and any resulting health effects are not yet established and will require further investigation.

The findings nonetheless have practical implications for departments weighing gear purchases. "Turnout gear is really expensive—one set costs thousands of dollars—and firefighters often use these garments for many years. Fire departments must consider both the financial and personal safety costs of keeping or replacing gear," said coauthor R. Bryan Ormond, an associate professor at NC State's Wilson College of Textiles who studies trade-offs in gear performance, in comments released by Duke.

Stapleton said some gear suppliers have now begun offering garments that avoid both PFAS and brominated flame retardants. She and her coauthors have called for greater transparency from manufacturers about the chemical treatments used in turnout gear so that departments and firefighters can make more informed decisions. "We know firefighters receive higher exposure to multiple chemicals from all the hazards they face during their duty, and they shouldn't have to worry about receiving additional chemical exposures from their gear," she said in Duke's summary of the research.

The study was conducted in collaboration with the International Association of Fire Fighters and is part of a broader effort by the Duke team to understand and reduce chemical risks facing firefighters.

사람들이 말하는 것

X users discuss a U.S. study finding brominated flame retardants in firefighter turnout gear, including PFAS-free models, at levels sometimes higher than PFAS. Concerns focus on health risks from replacement chemicals known to be toxic. Some highlight policy changes and lawsuit implications for cancer claims borne by employers.

관련 기사

Lab scientist discovering cancer- and hormone-linked chemicals in hair extensions, per Silent Spring Institute study.
AI에 의해 생성된 이미지

Study finds cancer- and hormone-linked chemicals in many hair extensions

AI에 의해 보고됨 AI에 의해 생성된 이미지 사실 확인됨

A new peer-reviewed analysis by the Silent Spring Institute found dozens of potentially hazardous chemicals in popular hair extensions, including products made from human hair. Researchers detected substances associated with cancer, hormone disruption and other health concerns in nearly all of the 43 products tested, raising renewed questions about safety and ingredient transparency in a largely unregulated market.

The Dutch motorcycle gear brand Rev’it! is developing alternatives to per- and polyfluoroalkyl substances, known as PFAS, in its products. The company aims to maintain waterproof protection while addressing environmental concerns about these persistent chemicals. This effort reflects a wider shift in the technical apparel industry.

AI에 의해 보고됨

한국 정부는 유럽연합(EU)의 퍼-폴리플루오로알킬물질(PFAS) 퇴출 계획에 대응하기 위해 현지 산업 관계자와 공동 태스크포스를 구성했다. EU는 이달 말 PFAS 제한 초안 의견을 발표할 예정이며, 2027년까지 전면 도입을 목표로 한다.

미군 기지 주변에서 PFAS가 검출된 후 오키나와의 기지 현장 검사 요청을 거부했다. 일본 방위성은 금요일 이 결정을 발표했다. 거부 이유는 기지와 오염을 연결하는 명확한 증거 부족과 현 샘플링 계획의 결함이다.

AI에 의해 보고됨

A new study reveals that wildfires and prescribed burns release about 21% more organic compounds into the atmosphere than previously estimated, contributing significantly to air pollution. These emissions, particularly intermediate- and semi-volatile organic compounds, can form harmful fine particles that linger in the air. The findings highlight overlaps with human-made pollution in regions like Southeast Asia, complicating efforts to improve air quality.

중국 연구자들이 혁신적인 유기 양극 재료를 개발해 배터리가 영하에서 80도까지 극한 온도에서 효율적이고 안정적으로 작동할 수 있게 했다. 이 재료는 기존 리튬이온 배터리의 비용 및 안전 문제를 해결하며 웨어러블 기기에 잠재력을 지닌다. 천진대학의 쉬윈화와 화난리공대학의 황페이가 이끈 연구는 2월 18일 네이처에 게재됐다.

AI에 의해 보고됨

Nearly one in 10 homes tested in the UK, Italy and the Netherlands showed benzene levels from gas cooker leaks that surpass safety limits, according to researchers. The cancer-causing chemical in natural gas poses risks akin to secondhand smoke indoors. The findings highlight potential indoor air pollution from slow leaks.

 

 

 